| Technical
Data
|
Gases
/ warranty
Combustible
gases (CH4)
Oxygen (O2)
Carbon monoxide (CO)
Hydrogen sulfide (H2S)
COSH (dual channel CO and H2S sensor)
|
Alarms
| Audible |
- 103 dB at 30 cm
(restrictable to 95 dB) |
| Visual |
- Bright, rotating 360° LED's, plus
heterochromatic backlit display |
| Vibrating
alarm |
|
Detection
range and resolution
CH4
|
0-100%
LEL |
0.5% |
| CH4 |
0-5% volume
|
0.05% |
| O2
|
0-25% volume
|
0.1% |
| CO |
0-300 ppm
|
1 ppm |
| H2S
|
0-100 ppm
|
1 ppm |
| COSH |
CO (0-300
ppm) and
H2S (0-100 ppm) |
1 ppm |
|
Casing
IP 67 (dust and highly water resistant) |
Accessories
Datalogging
kit
Self powered detachable sample pump (run-time up to 25 hours)
Spare battery cartridges (alkaline or rechargeable)
Rechargeable (NiMh) battery cartridge with optional LED flashlight |
Expected
sensor lifetime
| CH4 |
3-5
years |
| O2
|
3
years |
| CO
|
up
to 4 years |
| H2S |
3
years |
| COSH |
3
years |
|
Weight
0.62 pounds (280 g) |
Dimensions
4.4x2.6x2 inches (66x11.8x50.8 mm) (HxWxD) |
Rating
and certifications (intrinsic
safety)
cCSAus
Class I, Division 1, Group A, B, C, and D
Hazardous locations Temp code T3
|
Operational
time
Up to 25 hours |
Charge
time
4 hours with rechargeable NiMh cartridge |
Power
source
2 "AA" batteries or
rechargeable NiMh battery cartridge |
Temperature
range
-4° to +122°F (-20 to 50°C) ambient
5 to 95% r.h. (non-condensing) |