MWG EC25 EX EC25 EX
Technical Data

Measuring gas
Oxygen (O2)

Measuring range
0 .. 5 Vol%
0 .. 25 Vol %

Gas supply
Diffusion through sintered stainless steel filter

Humidity
15 .. 96 % r.F.

Pressure
920 .. 1100 hPa

Cable connection
PG9

Cable length to controller
4-20 mA signal:
Up to 300m (2x0,75mm2 cable)
Bigger 300m (2x1,5mm2 cable) shielded cable
0,2-1 mA signal:
Up to 300m (3x0,75mm2 cable)
Bigger 300m (3x1,5mm2 cable) shielded cable

Response Time
TAlarm < 8 seconds

Output signal
0,2 ..1 mA oder 4 .. 20 mA

Power supply
12 .. 24 V, 4 mA

Ambient temperature
-15 .. +45 °C
0 .. +40 °C tested

Sensor life
Longer than 12 months

Casing protection
IP 54

Dimensions
120 x 175 x 95 (WxHXD)

Weight
1500 g

Ex Approval
EEx ia IIC T6 (mit Ex-Barriere)

Type Certificate
DMT-BVS-Nr. 91C2033