CC24EX CC24EX
Technical Data

Measuring gas
Combustible gases (see tables)

Measuring range
0 .. 50 to 0 ..100 % LEL
Respectively in ppm range (see tables)

Gas supply
Diffusion through sintered stainless steel filter

Response time
TAlarm< 8 seconds (depending on the type of gas)

Humidity
5 .. 90 % r.H.

Pressure
920 .. 1080 hPa

Cable connection
PG11

Sensor life
About 5 years

Casing protection
IP 54 / IP 68 up to 10 m (Option)

Cable length to controller
Up to 300m (3x0,75mm cable)
Bigger 300m (3x1,5 mm cable) shielded cable

Output signal
0,2 ..1 mA or 4..20 mA

Power supply
18..24 V, 100 mA

Ambient temperature
-20...+40 °C tested (ex-approval)
-20...+55 °C (function-tested)

Dimensions
80 x 125 x 57 cm(WxHxD)

Weight
980 g

Ex-Approval
EEx dem [ib] IIC T6
BVS 94.C.2071 U, BVS 94.Y.6003 U