Technical Data
Measuring gas
Combustible gases (see tables)
Measuring range
0 .. 50 to 0 ..100 % LEL
Respectively in ppm range (see tables)
Gas supply
Diffusion through sintered stainless steel filter
Response time
TAlarm< 8 seconds (depending on the type of gas)
Humidity
5 .. 90 % r.H.
Pressure
920 .. 1080 hPa
Cable connection
PG11
Sensor life
About 5 years
Casing protection
IP 54 / IP 68 up to 10 m (Option)
Cable length to controller
Up to 300m (3x0,75mm cable)
Bigger 300m (3x1,5 mm cable) shielded cable
Output signal
0,2 ..1 mA or 4..20 mA
Power supply
18..24 V, 100 mA
Ambient temperature
-20...+40 °C tested (ex-approval)
-20...+55 °C (function-tested)
Dimensions
80 x 125 x 57 cm(WxHxD)
Weight
980 g
Ex-Approval
EEx dem [ib] IIC T6
BVS 94.C.2071 U, BVS 94.Y.6003 U
|
|